aboutsummaryrefslogblamecommitdiff
path: root/etc/rc.d/mdconfig2
blob: 4b1535e8e7c54589a63f12304ab1ff659fd424c8 (plain) (tree)





































                                                                            

                                          










                                          
 







































                                                                                                      




















                                                                                                       









                                                                                


                                                                        


































































































                                                                                                     
 
                                  
#!/bin/sh
#
# Copyright (c) 2006  The FreeBSD Project
# All rights reserved.
#
# Redistribution and use in source and binary forms, with or without
# modification, are permitted provided that the following conditions
# are met:
# 1. Redistributions of source code must retain the above copyright
#    notice, this list of conditions and the following disclaimer.
# 2. Redistributions in binary form must reproduce the above copyright
#    notice, this list of conditions and the following disclaimer in the
#    documentation and/or other materials provided with the distribution.
#
# THIS SOFTWARE IS PROVIDED BY THE AUTHOR AND CONTRIBUTORS ``AS IS'' AND
# ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
# IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
# ARE DISCLAIMED.  IN NO EVENT SHALL THE AUTHOR OR CONTRIBUTORS BE LIABLE
# FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
# DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
# OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
# HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
# LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
# OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
# SUCH DAMAGE.
#
# $FreeBSD$
#

# PROVIDE: mdconfig2
# REQUIRE: mountcritremote
# BEFORE: SERVERS

. /etc/rc.subr

name="mdconfig2"
stop_cmd="mdconfig2_stop"
start_cmd="mdconfig2_start"
start_precmd='[ -n "${_mdconfig2_list}" ]'
required_modules="geom_md:g_md"

is_readonly()
{
	local _mp _ret

	_mp=$1
	_ret=`mount | while read _line; do
		case ${_line} in
		*" ${_mp} "*read-only*)
			echo "yes"
			;;

		*)
			;;
		esac;
	done`

	if [ -n "${_ret}" ]; then
		return 0
	else
		return 1
	fi
}

init_variables()
{
	local _i

	_fs=""
	_mp=""
	_mounted="no"
	_dev="/dev/${_md}"
	eval _config=\$mdconfig_${_md}
	eval _owner=\$mdconfig_${_md}_owner
	eval _perms=\$mdconfig_${_md}_perms
	eval _files=\$mdconfig_${_md}_files
	eval _populate=\$mdconfig_${_md}_cmd

	_type=${_config##*-t\ }
	_type=${_type%%\ *}
	if [ -z "${_type}" ]; then
		err 1 "You need to specify \"-t <type>\" in mdconfig_${_md}"
	fi

	if [ "${_type}" = "vnode" ]; then
		_file=${_config##*-f\ }
		_file=${_file%%\ *}
		if [ -z "${_file}" ]; then
			err 2 "You need to specify \"-f <file>\" in mdconfig_${_md} for vnode devices"
		fi

		if [ "${_file}" != "${_file%.uzip}" ]; then
			_dev="/dev/${_md}.uzip"
		fi
		for _i in `df ${_file} 2>/dev/null`; do _fs=${_i}; done
	fi

	# Debugging help.
	debug "${_md} config: ${_config}"
	debug "${_md} type: ${_type}"
	debug "${_md} dev: ${_dev}"
	debug "${_md} file: ${_file}"
	debug "${_md} fs: ${_fs}"
	debug "${_md} owner: ${_owner}"
	debug "${_md} perms: ${_perms}"
	debug "${_md} files: ${_files}"
	debug "${_md} populate cmd: ${_populate}"
}

mdconfig2_start()
{
	local _md _fs _mp _mounted _dev _config _type _file _owner _perms _files _populate _fsck_cmd _i

	for _md in ${_mdconfig2_list}; do
		init_variables ${_md}
		if [ ! -r ${_file} ]; then
			err 3 "${_file} doesn't exist"
			continue
		fi
		# First pass: create md(4) vnode devices from files stored on
		# non-root partition. Swap and malloc md(4) devices have already
		# been created.
		if [ "${_type}" = "vnode" -a "${_fs}" != "/" ]; then
			if [ "${_file}" != "${_file%.uzip}" ]; then
				load_kld -m g_uzip geom_uzip || return 3
			fi
			if is_readonly ${_fs}; then
				warn "${_fs} is mounted read-only, skipping ${_md}."
				continue
			fi
			if mdconfig -l -u ${_md} >/dev/null 2>&1; then
				err 3 "${_md} already exists"
			fi
			echo "Creating ${_md} device (${_type})."
			if ! mdconfig -a ${_config} -u ${_md}; then
				echo "Creating ${_md} device failed, moving on."
				continue
			fi
			# Skip fsck for uzip devices.
			if [ "${_file}" != "${_file%.uzip}" ]; then
				_fsck_cmd=":"
			elif checkyesno background_fsck; then
				_fsck_cmd="fsck -F"
			else
				_fsck_cmd="fsck"
			fi
			if ! eval ${_fsck_cmd} -p ${_dev} >/dev/null; then
				echo "Fsck failed on ${_dev}, not mounting the filesystem."
				continue
			fi
			if mount -d ${_dev} >/dev/null 2>&1; then
				echo "Mounting ${_dev}."
				mount ${_dev}
			fi
		fi

		for _i in `df ${_dev} 2>/dev/null`; do _mp=${_i}; done
		if [ ! -z "${_mp}" -a "${_mp}" = "${_mp%%%}" ]; then
			_mounted="yes"
		fi

		if checkyesno _mounted; then
			# Second pass: change permissions and ownership.
			[ -z "${_owner}" ] || chown -f ${_owner} ${_dev} ${_mp}
			[ -z "${_perms}" ] || chmod -f ${_perms} ${_dev} ${_mp}

			# Third pass: populate with foreign files.
			if [ -n "${_files}" -o -n "${_populate}" ]; then
				echo "Populating ${_dev}."
			fi
			if [ -n "${_files}" ]; then
				cp -Rp ${_files} ${_mp}
			fi
			if [ -n "${_populate}" ]; then
				eval ${_populate}
			fi
		fi
	done
}

mdconfig2_stop()
{
	local _md _fs _mp _mounted _dev _config _type _file _owner _perms _files _populate

	for _md in ${_mdconfig2_list}; do
		init_variables ${_md}
		if [ "${_type}" = "vnode" ]; then
			for i in `df ${_dev} 2>/dev/null`; do _mp=$i; done
			if [ ! -r "${_file}" -o "${_fs}" = "/" ]; then
				continue
			fi
			if [ -z "${_mp}" -o "${_mp}" != "${_mp%%%}" ]; then
				echo "Device ${_dev} isn't mounted."
			else
				echo "Umounting ${_dev}."
				umount ${_dev}
			fi
			if mdconfig -l -u ${_md} >/dev/null 2>&1; then
				echo "Destroying ${_md}."
				mdconfig -d -u ${_md}
			fi
		fi
	done
}

_mdconfig2_cmd="$1"
if [ $# -gt 0 ]; then
        shift
fi
[ -n "$*" ] && _mdconfig2_list="$*"

load_rc_config $name

_mdconfig2_unit=0
if [ -z "${_mdconfig2_list}" ]; then
	while :; do
		eval _mdconfig2_config=\$mdconfig_md${_mdconfig2_unit}
		if [ -z "${_mdconfig2_config}" ]; then
			break
		else
			_mdconfig2_list="${_mdconfig2_list}${_mdconfig2_list:+ }md${_mdconfig2_unit}"
			_mdconfig2_unit=$((${_mdconfig2_unit} + 1))
		fi
	done
fi

run_rc_command "${_mdconfig2_cmd}"